V06

Power class: 4 A to 25 A
Series: 06

  • normally closed
  • resets automatically
  • with connector cables
  • double-insulated in the attachment housing
Download Datasheet
Thermal protectors V06Thermal protectors V06

Technical specifications

Nominal switching temperature (NST) in 5 °C 70 °C - 180 °C
Tolerance (standard) ±5 K
Reverse switch temperature (RST) below NST UL ≥ 35° C (≤ 95° C NST)#-50 K ± 15 K (≥ 100° C ≤ 180° C NST)
Reverse switch temperature (RST) below NST VDE ≥ 35 °C
Installation height from 10.0 mm
Housing size (length/width) 26.0 mm / 13.5 mm
Fixing/Max. torque 2.5 Nm
Resistance to impregnation suitable
Suitable for installation in protection class II
Pressure resistance to the switch housing 600 N
Standard connectionLead wire 0.5 mm² / AWG20
Operational voltage range AC/DCup until 500 V AC / 28 V DC
Rated voltage AC250 V (VDE) 277 V (UL)
Rated current AC cos ϕ = 1.0/cycles10.0 A / 10,000
Rated current AC cos ϕ = 0.6/cycles6.3 A / 10,000
Max. switching current AC cos ϕ = 1.0/cycles25.0 A / 2,000
Rated voltage DC24 V
Max. switching current DC/cycles40.0 A / 8,000
High voltage resistance3.75 kV
Total bounce time< 1 ms
Contact resistance (according to MIL-STD. R5757)≤ 50 mΩ
Vibration resistance at 10 ... 60 Hz100 m/s²

Approbation

IECENECVDECQC
Go to Top To the top