Nominal switching temperature (NST) in 5 °C
50 °C - 200 °C
Tolerance (standard)
±5 K
Reverse switch temperature (RST) below NST UL
≥ 35° C (≤ 80° C NST)#-35 K ± 15 K (≥ 85°C ≤ 180° C NST)
Reverse switch temperature (RST) below NST VDE
≥ 35 °C
Housing height
from 8.0 mm
Diameter
12.0 mm
Thread/Length
M6 x 8.0 mm
Width across flats/Max. torque
13.0 mm / 8 Nm
Resistance to impregnation
suitable
Suitable for installation in protection class
I + II
Pressure resistance to the switch housing
300 N
Standard connection
Lead wire 0.5 mm² / AWG20
Operational voltage range AC/DCup until 500 V AC / 14 V DC
Rated voltage AC250 V (VDE) 277 V (UL)
Rated current AC cos ϕ = 1.0/cycles6.3 A / 10,000
Rated current AC cos ϕ = 0.6/cycles4.0 A / 10,000
Max. switching current AC cos ϕ = 1.0/cycles10.0 A / 3,000
Max. switching current AC cos ϕ = 1.0/cycles20.0 A / 300
Rated current AC cos ϕ = 0.4/cycles4.6 A / 10,000
Max. switching current AC cos ϕ = 0.4/cycles18.4 A / 1,000
Rated voltage DC12 V (VDE, UL)
Max. switching current DC/cycles40.0 A / 10,000
High voltage resistance2.0 kV
Total bounce time< 1 ms
Contact resistance (according to MIL-STD. R5757)≤ 50 mΩ
Vibration resistance at 10 ... 60 Hz100 m/s²
Approbation
IECENECVDEUL (appr.≤ 180°C)CSACQC