CXH

Power class: 25 A to 75 A
Series: XH

  • normally closed
  • resets automatically
  • with connector cables
  • hybrid
  • without insulation
Download Datasheet
Thermal protectors CXH

Technical specifications

Nominal switching temperature (NST) in 5 °C 70 °C - 180 °C
Tolerance (standard) ±10 K
Reverse switch temperature (RST) below NST UL ≥ 35° C (≤ 130° C NST)# -85 K ± 15 K (≥ 135° C ≤ 190° C NST)
Reverse switch temperature (RST) below NST VDE ≥ 35 °C
Construction, two parts CH6 standard
Lead wire length customer specific
Electronic arc extinction 48,0 x 42.5 x 19.0 mm
Resistance to impregnation suitable
Suitable for installation in protection classI
Standard connectionLead wire 1.0 mm² / AWG18
Operating voltage range ACup until 250 V AC
Rated voltage AC250 V
Rated current AC cos ϕ = 1.0/cycles13.5 A / 10,000
Max. switching current AC cos ϕ = 1.0/cycles65.0 A / 10,000
Total bounce time< 10 µs
Contact resistance (according to MIL-STD. R5757)≤ 25 mΩ
Vibration resistance at 10 ... 60 Hz100 m/s²

Approbation

IECENECVDE
Go to Top To the top