CH6

Power class: 13.5 A to 42 A
Series: H6

  • normally closed
  • resets automatically
  • with connector cables
  • with epoxy
  • without insulation
Download Datasheet
Thermal protectors CH6Thermal protectors CH6Thermal protectors CH6

Technical specifications

Nominal switching temperature (NST) in 5 °C 70 °C - 200 °C
Tolerance NST ≤ 140 °C ±5K
Tolerance NST > 140 °C ±10K
Reverse switch temperature (RST) below NST UL ≥ 35° C (≤ 130° C NST)# -85 K ± 15 K (≥ 135° C ≤ 190° C NST)#-90 K ± 15 K(≥ 195° C ≤ 200° C NST)
Reverse switch temperature (RST) below NST VDE ≥ 35 °C
Installation height from 6.8 mm
Diameter 9.0 mm
Resistance to impregnation suitable
Suitable for installation in protection class I
Pressure resistance to the switch housing 600 N
Standard connectionLead wire 1.0 mm² / AWG18
Operational voltage range AC/DCup until 500 V AC / 28 V DC
Rated voltage AC250 V (VDE) 277 V (UL)
Rated current AC cos ϕ = 1.0/cycles13.5 A / 10,000
Rated current AC cos ϕ = 0.6/cycles9.0 A / 10,000
Max. switching current AC cos ϕ = 1.0/cycles35.0 A / 2,000
Max. switching current AC cos ϕ = 1.0/cycles42.0 A / 300
Rated voltage DC24 V (VDE, UL)
Max. switching current DC/cycles60.0 A / 3,000
Total bounce time< 1 ms
Contact resistance (according to MIL-STD. R5757)≤ 50 mΩ
Vibration resistance at 10 ... 60 Hz100 m/s²

Approbation

IECVDEULCQCCMJ
Go to Top To the top