V08 - Thermal-Protectors
Thermik ® 3D Product-Viewer

Just click on the picture to rotate the product atomaticly or use the arrow buttons. To display more information just hover the "Hot-Spots".

Drawings and further Pictures

Further information for this
product for download

Data sheet (PDF)
Product pictures (JPG/ZIP)
3D Data (STEP-Format)

Contactor V08 - request at
Thermik without obligation...

Name:

Company:

Phone (with country code):

Email:

Location

Technical details of V08:
Every important detail at a glance!

Automatic resetting, with mountable housing and double insulation, suitable for protection class II

  1. Contact type: normally open

  2. Nominal switching temperature (NST) in steps of 5 °C:

    70 °C - 180 °C

  3. Standard tolerance: ± 5K

  4. Reset temperature range below NST (UL / CSA):

    depends on NST

  5. Operating voltage … AC / DC - available,
    values on inquiry: up to 500 V ~

  6. Rated voltage UAC: 250 V (VDE)

  7. Rated current AC cos φ = 1.0 (ohmic load) / switching cycles:

    10.0 A / 10,000
    25.0 A / 2,000*

  8. Rated current AC cos φ = 0.6 acc. to IEC 60730-2-9 / switching cycles:

    6.3 A / 10,000

  9. Contact bounce time: < 1 ms

  10. Contact resistance (acc. to MIL-Std. R 5757): < 50 mΩ

  11. Impregnation resistance with- or without resin
    (acc. to requirements)*: suitable

  12. Vibration proof at 10 … 60 Hz: 100 m/s²

  13. Pressure stability of housing *: 600 N

  14. High voltage insulation (not C - versions): 3.75 kV

  15. Suitable for protection class I or II: suitable

  16. Standard wiring connection: lead wire 0.5 mm² / AWG 20

  17. Heigth: 10.0 mm

  18. Length of housing: 26.0 mm / 13.5 mm

  19. Wrench size / max. turning moment: 2.5 Nm

  20. Approvals available (according to design): IEC; ENEC; VDE; CQC