Technical details of C06:
Every important detail at a glance!
Automatic resetting, with connection leads
Contact type: normally closed
Nominal switching temperature (NST) in steps of 5 °C:
70 °C - 200 °C
Standard tolerance: ± 5K
Reset temperature range below NST (UL / CSA):
depends on NST
Operating voltage … AC / DC - available,
values on inquiry: up to 500 V ~Rated voltage UAC: 250 V (VDE) 277 V (UL)
Rated current AC cos φ = 1.0 (ohmic load) / switching cycles:
10.0 A / 10,000
25.0 A / 2,000*Rated current AC cos φ = 0.6 acc. to IEC 60730-2-9 / switching cycles:
6.3 A / 10,000
Contact bounce time: < 1 ms
Contact resistance (acc. to MIL-Std. R 5757): < 50 mΩ
Impregnation resistance with- or without resin
(acc. to requirements)*: suitableVibration proof at 10 … 60 Hz: 100 m/s²
Pressure stability of housing *: 600 N
Suitable for protection class I or II: suitable
Standard wiring connection: lead wire 0.75 mm² / AWG18
Diameter: 9.3 mm
Heigth: 7.2 mm
Approvals available (according to design): IEC; ENEC; VDE; UL; CSA; CQC
* Erweiterter Temperaturbereich: Dieser Schalter ist bis zu einer Nennschalttemperatur von 250° C in unserer Hoch-Temperatur-Serie verfügbar.